Model No.:GST15

Product Name:15A/125V GFCI Receptacle (TR)


Description:

1. Constructed with premium high-impact resistant PC materials and rational structure design, 

    ensures superior strength and durability.

2. With Tamper Resistant shutter

3. The self-test GFCI automatically detects an internal test every 1-20 minutes. The red indictor 

    light will flash once quickly during the detection. After pressing the RESET button , the green

    indicator light will be on, indicating that the device is working normally. If the device fails

    the test, the red indicator light will stay on, or the device automatically trips, reminding the

    user that the device should be replaced. 

4. This device has triple detection function: ① Automatic detection; ② Manual testing by the

   TEST button; ③ Tested by the RESET button.

5. Flame retardant grade rated V-0, exceeds the flame retardant grade specified by UL.


GST15-2.jpg


GST15带自接地片.jpg


GST15带面板.jpg


Certificate: cULus file No. E524399.

Standards: Meets 2018 UL 943 and CSA C22.2 NO. 144.1-16 requirements.

 

Specifications:

Product Size: 105*42*42.5mm

Product Weight: 120g (wall plate and installing screws included )

Rated parameters: 15A/125Vac/60Hz

Termination: Back & Side

Ground fault action current: 4-6mA

Trip Threshold: 4-6mA

Trip Time: <25mS

Flame retardant grade: V-0

Auto-Monitoring Function Test Repeat Test Interval: 1S

Wires: 12-14AWG

Operation Temperature: -35℃~66℃